Box Gutter Regulations Nsw
Rainhead overflow or specific box gutter overflow must be at least 30mm below the height of the back of the box gutter.
Box gutter regulations nsw. The depth shown in the calculations is at the upstream end. This will prevent water damage in the event of gutters overflowing either due to high rainfall or a blockage. For commercial projects the minimum allowable width is 300mm. Stratco gutters are strong yet lightweight making them easy to handle.
Read more about compliant guttering options. All domestic box gutters must be a minimum of 200mm wide and 75mm deep. Required gutter slope 1 40 to 1 200. Box gutters must be straight no bends.
The regulations require that guttering has allowances for water to overflow gutters in a way that does not cause water to flow back into the structure. There is detailed government legislation regarding the design installation and maintenance of guttering. The builder or guttering installer needs to make sure the gutter system is fully compliant with nsw laws and australian standards. Always check the measurements of your building and work out exactly how much downpipe will be serving each gutter.
Code box gutter requirements the minimum width allowed for domestic projects is 200mm. There is always some confusion as to how the slope affects the overall depth. Understanding the ncc gutter and downpipe provisions for housing includes information for building designers hydraulic consultants plumbers builders and other onsite trades about the selection and installation of gutters and downpipes including overflow measures. In victoria the installation of box gutters is regulated plumbing work that must be carried out and certified by suitably registered licensed plumbers.
You do not want to put extra pressure on the system. Examples of box gutters are shown below. Plumbers must install a box gutter system in accordance with as nzs 3500 3 as nzs 3500 5 hb 114 and hb 39. Pre manufactured gutter mitres and gutter angles for many guttering profiles reduce the need for creating mitres on site therefore simplifying the installation.
Minimum width 300 mm for commercial construction and 200 mm for domestic construction. Downpipes should not serve more than 12 metres of gutter length for each downpipe. This effectively states that all box gutters must allow for 30mm of freeboard which is from the overflow point eg.